- Reverse Cycle (Heating & Cooling)
- Cooling Only
- Smartphone Control (optional)
Lite Systems
Wall Mounted
Designed with the latest cutting-edge technologies, the Lite and Multi Lite systems features a compact modern design, delivering air conditioned comfort more quietly than ever before.
Best For:
- Heating or cooling of small to large rooms
- Those looking for economical air conditioning
- When floor standing units are not an option
Floor Standing
Floor Standing
Daikin’s floor standing air conditioning units are compact and ideal for anyone wanting the convenience and access of positioning their unit closer to the floor.
Best For:
- Heating or cooling of small rooms
- Those requiring a small installation footprint
- Colder climates where heating is a priority
Compare Product Features
Rotate for best viewing experience
Cora | Lite | XL Series | Floor Standing | |
---|---|---|---|---|
DC Inverter
DC Inverter motor is Daikin’s term for an inverter air conditioner equipped with a DC motor. These motors use magnets to generate rotation, making them more efficient than AC motors. Our advanced DC motors for compressors are fitted with powerful neodymium magnets to achieve even greater efficiency. We call these devices Reluctance DC motors. |
||||
PAM Control
PAM stands for pulse amplitude modulation, a technology that controls the supply current waveform so that it resembles the supply voltage wave, this enables more efficient use of electricity. |
||||
Standby Power Function
When the air conditioner is not in use, the Standby Power Function turns off power supply to the outdoor unit and sets the indoor unit into standby energy saving mode, reducing energy consumption. |
||||
Indoor Unit Quiet Operation
Sound levels are reduced by 2-3 decibels (dBA) from the low fan speed for quieter heating and cooling. |
||||
Outdoor Unit Quiet Operation
Outdoor unit sound levels can be reduced by 3 decibels (dBA) for times when quieter operation is needed. |
||||
Automatic Operation
Airflow is optimised to suit contamination levels for efficient energy usage. |
||||
Program Dry Function
The system reduces the humidity in the room while maintaining the temperature as much as possible. It automatically controls the temperature and airflow rate and will switch into cooling mode if the room temperature increases too much. |
||||
Auto Fan Speed
To reduce operating noise, the fan speed is automatically controlled by the micro-processor to suit the thermostat setting and prevailing room temperature. |
||||
Air-Purifying Filter
Traps microscopic particles. |
||||
Econo Mode
Controls the upper limit of frequency, reducing power consumption. This reduces the load on the electrical circuit when multiple electrical devices are used simultaneously. |
||||
Powerful Operation
Pushing the POWERFUL button on the remote control gives you a boost in cooling or heating power for a 20 minute period, even if the unit is already operating at high capacity. |
||||
Indoor Unit On/Off Switch
Physical switch on the indoor unit for switching the unit on or off. |
||||
Night Set Mode
Through the use of the ‘Timer Off Circuit’, the preset room temperature gently rises in cooling or falls in heating before the unit stops. This energy efficient feature allows you to sleep comfortably without feeling a sudden change in the room temperature. |
||||
Auto Restart after Power Failure
The unit memorises the operation mode, airflow and temperature settings. Should there be a power failure when the unit is in operation, it will automatically return to the same operating conditions when the power is restored. |
||||
Self Diagnosis with Digital Display
In the unlikely event that a problem develops with the unit, malfunction codes can be displayed on the liquid crystal panel of the remote control for fast and easy fault diagnosis. |
||||
Anti-Corrosion Treatment of Outdoor Heat Exchanger
The special anti-corrosion coating on the outdoor unit heat exchanger ensures greater resistance to salt damage and atmospheric corrosion. |
||||
Hot Start
When heating commences, or when changing from cooling to heating, airflow doesn't start until the air is warm, preventing cold draughts. |
4 | 4 | ||
Power-Airflow Dual Flaps
Power-Airflow dual flaps can flatten out during cooling operation to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation. |
2 | 2 | ||
0.5°C Step Room Temperature Control
Room temperature can be adjusted precisely in increments of 0.5°C to ensure optimal comfort conditions. |
3 | 3 | ||
Power-Airflow Flaps
Power-Airflow flaps can flatten out during cooling operatin to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation. |
1 | 1 | ||
Horizontal Auto-Swing
This function automatically moves the louvres to the left and right to cover the room with cool/warm air. |
||||
3D Airflow
Combines vertical and horizontal auto-swing to circulate cool/warm air to the corners of large spaces. |
||||
Comfortable Airflow Mode
The flap changes the delivery angle to horizontal for cooling and vertical for heating operation, to prevent cold or warm air from blowing directly onto your body. |
||||
Intelligent Eye
This is an infrared motion sensor with the ability to sense movement in the room. When you are in the room, the air conditioner operates normally. If no activity is detected in a room for more than 20 minutes the air conditioner automatically changes to an energy saving operation.. |
2 | |||
2-Area Inteligent Eye
The 2-Area Intelligent eye either directs airflow towards you (Alira & Cora Only) or away from you for draught free comfort or when both areas are occupied, automatically activate comfort airflow mode to maintain conditions in both areas. If the room is unoccupied for 20 minutes, the unit automatically goes into energy saving operations. |
1 | |||
Titanium Apatite Deoderising Filter
Traps microscopic particles, decomposes odours and helps absorb and deactivates bacteria to purify the air in your room. |
||||
24 Hour On/Off Timer
The timer can be preset to start and stop the air conditioner at any time within a 24 hour period. Once the times are set, the air conditioner can be operated for a period by simply pressing the on or off timer buttons. |
||||
Weekly Timer
This function makes it easy to enter up to four settings per day for each day of the week. It not only allows you to program on and off time, but also the desired temperature. |
- Only available for 20-46 Class (20-50 Class for Lite Systems)
- Only available for 50-95 Class (60-71 Class for Lite Systems)
- Only available for 20-71 Class
- Only available for Reverse Cycle models
- Optional Accessory
- Optional Accessory, Remote Control PCB also required
Why choose Daikin?
Specialist Dealer Network
Quality After Sales Support
Sensitive Choice® Approved
Please upgrade your browser for a better experience.
Upgrade your browser today