Product Details & Specifications

Daikin Connect

Learn more about Cora, Lite, XL and Floor Standing and compare product features

  • Reverse Cycle (Heating & Cooling)
  • Cooling Only
  • Smartphone Control (optional)
Cora

Cora

Wall Mounted

Delivered in understated confidence, featuring whisper quiet operation, improved energy efficiency and reliability without compromising on style.

Best For:

  • Heating or cooling of small to large rooms
  • Those that are conscious of energy usage
  • Maintaining room ambience
XL Series

XL Series

Wall Mounted

Powerful airflow delivery, large capacity models designed for large open plan living. Available in two ranges, XL and the more energy efficient XL Premium.

Best For:

  • Heating or cooling large open plan living spaces
Lite Systems

Lite Systems

Wall Mounted

Designed with the latest cutting-edge technologies, the Lite and Multi Lite systems features a compact modern design, delivering air conditioned comfort more quietly than ever before.

Best For:

  • Heating or cooling of small to large rooms
  • Those looking for economical air conditioning
  • When floor standing units are not an option
Floor Standing

Floor Standing

Floor Standing

Daikin’s floor standing air conditioning units are compact and ideal for anyone wanting the convenience and access of positioning their unit closer to the floor.

Best For:

  • Heating or cooling of small rooms
  • Those requiring a small installation footprint
  • Colder climates where heating is a priority

Compare Product Features

Rotate for best viewing experience

Cora Lite XL Series Floor Standing
DC Inverter

DC Inverter motor is Daikin’s term for an inverter air conditioner equipped with a DC motor. These motors use magnets to generate rotation, making them more efficient than AC motors. Our advanced DC motors for compressors are fitted with powerful neodymium magnets to achieve even greater efficiency. We call these devices Reluctance DC motors.

PAM Control

PAM stands for pulse amplitude modulation, a technology that controls the supply current waveform so that it resembles the supply voltage wave, this enables more efficient use of electricity.

Standby Power Function

When the air conditioner is not in use, the Standby Power Function turns off power supply to the outdoor unit and sets the indoor unit into standby energy saving mode, reducing energy consumption.

Indoor Unit Quiet Operation

Sound levels are reduced by 2-3 decibels (dBA) from the low fan speed for quieter heating and cooling.

Outdoor Unit Quiet Operation

Outdoor unit sound levels can be reduced by 3 decibels (dBA) for times when quieter operation is needed.

Automatic Operation

Airflow is optimised to suit contamination levels for efficient energy usage.

Program Dry Function

The system reduces the humidity in the room while maintaining the temperature as much as possible. It automatically controls the temperature and airflow rate and will switch into cooling mode if the room temperature increases too much.

Auto Fan Speed

To reduce operating noise, the fan speed is automatically controlled by the micro-processor to suit the thermostat setting and prevailing room temperature.

Air-Purifying Filter

Traps microscopic particles.

Econo Mode

Controls the upper limit of frequency, reducing power consumption. This reduces the load on the electrical circuit when multiple electrical devices are used simultaneously.

Powerful Operation

Pushing the POWERFUL button on the remote control gives you a boost in cooling or heating power for a 20 minute period, even if the unit is already operating at high capacity.

Indoor Unit On/Off Switch

Physical switch on the indoor unit for switching the unit on or off.

Night Set Mode

Through the use of the ‘Timer Off Circuit’, the preset room temperature gently rises in cooling or falls in heating before the unit stops. This energy efficient feature allows you to sleep comfortably without feeling a sudden change in the room temperature.

Auto Restart after Power Failure

The unit memorises the operation mode, airflow and temperature settings. Should there be a power failure when the unit is in operation, it will automatically return to the same operating conditions when the power is restored.

Self Diagnosis with Digital Display

In the unlikely event that a problem develops with the unit, malfunction codes can be displayed on the liquid crystal panel of the remote control for fast and easy fault diagnosis.

Anti-Corrosion Treatment of Outdoor Heat Exchanger

The special anti-corrosion coating on the outdoor unit heat exchanger ensures greater resistance to salt damage and atmospheric corrosion.

Hot Start

When heating commences, or when changing from cooling to heating, airflow doesn't start until the air is warm, preventing cold draughts.

4 4
Power-Airflow Dual Flaps

Power-Airflow dual flaps can flatten out during cooling operation to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation.

2 2
0.5°C Step Room Temperature Control

Room temperature can be adjusted precisely in increments of 0.5°C to ensure optimal comfort conditions.

3 3
Power-Airflow Flaps

Power-Airflow flaps can flatten out during cooling operatin to deliver cool air to the corners of a room. The flaps can direct warm air straight down to the floor during heating operation.

1 1
Horizontal Auto-Swing

This function automatically moves the louvres to the left and right to cover the room with cool/warm air.

3D Airflow

Combines vertical and horizontal auto-swing to circulate cool/warm air to the corners of large spaces.

Comfortable Airflow Mode

The flap changes the delivery angle to horizontal for cooling and vertical for heating operation, to prevent cold or warm air from blowing directly onto your body.

Intelligent Eye

This is an infrared motion sensor with the ability to sense movement in the room. When you are in the room, the air conditioner operates normally. If no activity is detected in a room for more than 20 minutes the air conditioner automatically changes to an energy saving operation..

2
2-Area Inteligent Eye

The 2-Area Intelligent eye either directs airflow towards you (Alira & Cora Only) or away from you for draught free comfort or when both areas are occupied, automatically activate comfort airflow mode to maintain conditions in both areas. If the room is unoccupied for 20 minutes, the unit automatically goes into energy saving operations.

1
Titanium Apatite Deoderising Filter

Traps microscopic particles, decomposes odours and helps absorb and deactivates bacteria to purify the air in your room.

24 Hour On/Off Timer

The timer can be preset to start and stop the air conditioner at any time within a 24 hour period. Once the times are set, the air conditioner can be operated for a period by simply pressing the on or off timer buttons.

Weekly Timer

This function makes it easy to enter up to four settings per day for each day of the week. It not only allows you to program on and off time, but also the desired temperature.

  1. Only available for 20-46 Class (20-50 Class for Lite Systems)
  2. Only available for 50-95 Class (60-71 Class for Lite Systems)
  3. Only available for 20-71 Class
  4. Only available for Reverse Cycle models
  5. Optional Accessory
  6. Optional Accessory, Remote Control PCB also required

Why choose Daikin?

Experts in Air Conditioning

Experts in Air Conditioning

Specialist Dealer Network

Specialist Dealer Network

Quality After Sales Support

Quality After Sales Support

Sensitive Choice® Approved

Sensitive Choice® Approved

Where to buy Daikin

A Daikin Specialist Dealer will assess, plan and install the right air conditioning solution for you, with creativity and sensitivity to the needs of your family or business.

*All appointed Daikin specialist dealers are independently owned and operated businesses
You appear to be using an outdated browser. Please upgrade your browser for a better experience. X
You appear to be using an outdated browser.
Please upgrade your browser for a better experience.
Upgrade your browser today